Issue Information
| Issue Number | 701026a |
| Issue | TEMP read/write used in parallel execution does not appear in XPLAN. |
| Cause | The process of passing the j_cnt difference value measured on the slave to the QC for aggregation was missing. |
| Resolution | Modify to pass the statistics measured on the slave to the QC for aggregation. |
| Occurrence Date | 06/10/2026 |
| Patch Required Versions | 6FS07PS 7FS02PS |
Patch Information
| Patch Name | FS02PS_701026a |
| Major Version | 7 |
| Minor Version | FS02PS |
| Version Title | Fix for TEMP read/write used in parallel execution not appearing in XPLAN |
| Release Date | 06/16/2026 |
| Compatibility | • TAC rolling patch: Supported • TSC rolling patch: Supported • Backup data compatibility: Supported • Protocol compatibility: Supported • Data format compatibility: Supported |
| AP Impact | • Plan change: No • Result value change: Yes • SQL syntax change: No • System object change: No • Existing feature change: No |
| Parameters | - |
| Workaround | - |