Issue Information
| Issue Number | 701026a |
| Issue | TEMP read/write used in parallel execution does not appear in XPLAN. |
| Cause | The process of passing the j_cnt difference value measured on the slave to the QC for aggregation is missing. |
| Resolution | Modify to pass the statistics measured on the slave to the QC for aggregation. |
| Occurrence Date | June 10, 2026 |
| Patch Required Versions | 6FS07PS 7FS02PS |
Patch Information
| Patch Name | FS02PS_701026a |
| Major Version | 7 |
| Minor Version | FS02PS |
| Version Title | Fix for temp read/write used in parallel execution not appearing in xplan |
| Release Date | June 16, 2026 |
| Compatibility | โข TAC rolling patch: Supported โข TSC rolling patch: Supported โข Backup data compatibility: Supported โข Protocol compatibility: Supported โข Data format compatibility: Supported |
| AP Impact | โข Plan change: No โข Result value change: Yes โข SQL syntax change: No โข System object change: No โข Existing feature change: No |
| Parameters | - |
| Workaround | - |