Issue Information
| Issue Number | 701718a |
| Issue | When MR is performed in a section containing tempfile drop redo, the datafile with the same ID is deleted from the CV, and an ERROR_TCCF_DD_CHECK_FAILED error occurs during the subsequent boot. |
| Cause | This occurs because tempfile is not considered when applying datafile drop redo during MR execution. |
| Solutions | Modify the datafile drop redo application logic to consider tempfile during MR execution. |
| Occurrence Date | 26.10.28. |
| Version Requiring the Patch | 6FS07PS 7FS02PS |
Patch Information
| Patch Name | FS02PS_701718a |
| Major Version | 7 |
| Minor Version | FS02PS |
| Version Title | Fix an error in which a datafile with the same number is deleted due to a tempfile drop CV during MR execution |
| Available for Deployment | 26.11.05. |
| Compatibility | • TAC rolling patch: Available • TSC rolling patch: Available • Backup data compatibility: Available • Protocol compatibility: Available • Data format compatibility: Available |
| AP Impact | • Plan change: No • Result value change: No • SQL syntax change: No • System object change: No • Existing functionality change: No |
| Parameters | - |
| Workaround | - |