Issue Information
| Issue Number | 701112a |
| Issue | After performing Media Recovery on an Offline Tablespace in NORMAL mode and rebooting, an ERROR_TCCF_DD_CHECK_FAILED(-24018) error occurs. |
| Cause | Online Media Recovery performed in NORMAL mode does not require CF-DD correction after completion, but it is mistakenly processed as if correction is needed. |
| Resolution | Modify the finalization logic during Media Recovery to branch according to Server Mode so that unnecessary CF-DD correction is not performed in NORMAL mode. |
| Occurrence Date | 07/08/2026 |
| Required Patch Versions | 6FS07PS 7FS02PS |
Patch Information
| Patch Name | FS02PS_701112a |
| Major Version | 7 |
| Minor Version | FS02PS |
| Version Title | Remove CF-DD Correction After Completing Online Media Recovery |
| Release Date | 08/07/2026 |
| Compatibility | โข TAC Rolling Patch: Supported โข TSC Rolling Patch: Supported โข Backup Data Compatibility: Supported โข Protocol Compatibility: Supported โข Data Format Compatibility: Supported |
| AP Impact | โข Plan Change: No โข Result Value Change: No โข SQL Syntax Change: No โข System Object Change: No โข Existing Feature Change: No |
| Parameters | - |
| Workaround | - |